Difference between revisions of "Table of Experimental Studies on CFT Connection Tests"
From Composite Systems
Line 12: | Line 12: | ||
|- | |- | ||
! scope="row" style="background-color:#efefef;"| [[Dunberry, LeBlanc, and Redwood 1987]] | ! scope="row" style="background-color:#efefef;"| [[Dunberry, LeBlanc, and Redwood 1987]] | ||
+ | | Axial loading of square stub columns through shear connections | ||
+ | | 18 CFTs | ||
+ | | Axial load applied at the top and at the connection simultaneously | ||
| | | | ||
+ | *P vs. ε<sub>s</sub>, ε<sub>concr</sub> | ||
+ | *L vs. d<sub>s</sub> (slip) | ||
+ | *L vs. P<sub>c</sub>, P<sub>s</sub> | ||
+ | *θ<sub>c</sub> vs. P | ||
| | | | ||
− | + | *Connection detail | |
− | + | *Connection load/total axial load | |
− | + | *D/t | |
+ | *End conditions (capped, uncapped) | ||
| | | | ||
|- | |- | ||
! scope="row" style="background-color:#efefef;"| [[Kamba, Kanatani, and Tabuchi 1991]] | ! scope="row" style="background-color:#efefef;"| [[Kamba, Kanatani, and Tabuchi 1991]] | ||
+ | | Shear tests of through diaphragm connections to square CFT and HT columns | ||
| | | | ||
+ | *5 CFTs | ||
+ | *5 HTs | ||
+ | | Shear couples acting on the diaphragm plates | ||
| | | | ||
+ | *σ-ε relations for steel | ||
+ | *V<sub>u</sub>, V<sub>y</sub>, K<sub>o</sub> | ||
+ | *V<sub>cu</sub>, V<sub>cy</sub>, K<sub>co</sub> | ||
+ | *V vs. γ | ||
+ | *τ<sub>c</sub> vs. γ | ||
| | | | ||
− | + | *D/t (column and panel zone) | |
− | + | *CFT vs. HT | |
+ | *Annealing of steel tube | ||
| | | | ||
|- | |- | ||
! scope="row" style="background-color:#efefef;"| [[Prion and McLellan 1992]] | ! scope="row" style="background-color:#efefef;"| [[Prion and McLellan 1992]] | ||
+ | | Through-bolt connections between steel wide-flange girders and CFTs | ||
+ | | 8 CFTs | ||
+ | | Tension pull-out and compression pull-in tests | ||
| | | | ||
− | + | *Concrete and steel stress-strain relationships | |
− | + | *Bolt slip-load and load-strain relationshops | |
− | + | | Post-tensioning of the bolts in the connection | |
− | | | ||
| | | | ||
|- | |- | ||
! scope="row" style="background-color:#efefef;"| [[Azizinamini and Prakash 1992]] | ! scope="row" style="background-color:#efefef;"| [[Azizinamini and Prakash 1992]] | ||
− | | | + | | Pass-through girder with internal stiffeners |
− | | | + | | 1 CFT |
− | | | + | | Shear forces were applied to the girder ends in opposite directions |
− | | | + | | N.A. |
− | | | + | | N.A. |
| | | | ||
|- | |- | ||
! scope="row" style="background-color:#efefef;"| [[Shakir-Khalil and Al-Rawdan 1995, 1996]] | ! scope="row" style="background-color:#efefef;"| [[Shakir-Khalil and Al-Rawdan 1995, 1996]] | ||
+ | | Full-scale simple interior beam-to-column connections of circular and square CFTs | ||
+ | | 28 CFTs | ||
| | | | ||
+ | *Symm. loading of the beams and axial loading of the column, simult. | ||
+ | *Beam-to-column load ratios were 1:8 or 1:5 | ||
| | | | ||
+ | *M vs. θ<sub>c</sub> | ||
+ | *K<sub>o</sub>, P<sub>u</sub> | ||
+ | *P vs. ε<sub>s</sub> | ||
| | | | ||
− | + | *Fin-plate vs. tee cleat | |
− | + | *D | |
+ | *t | ||
+ | *Shear connector | ||
+ | *Beam load to column load ratio | ||
+ | *Eccentricity of beam load | ||
| | | | ||
|- | |- | ||
! scope="row" style="background-color:#efefef;"| [[Shakir-Khalil and Al-Rawdan 1995, 1996]] | ! scope="row" style="background-color:#efefef;"| [[Shakir-Khalil and Al-Rawdan 1995, 1996]] | ||
+ | | Monotonic tests for full-scale simple exterior beam-to-column connections of square CFTs | ||
+ | | 4 CFTs | ||
| | | | ||
+ | *Eccentric loading of the beam and axial loading of the column, simult. | ||
+ | *Beam-to-column load ratios were 1:8 or 1:5 | ||
| | | | ||
+ | *M vs. θ<sub>c</sub> | ||
+ | *K<sub>o</sub>, P<sub>u</sub> | ||
+ | *Longitudinal strain distribution along the column length | ||
| | | | ||
− | + | *Beam load to column ratio | |
− | + | *Eccentricity of beam load | |
| | | | ||
|- | |- | ||
! scope="row" style="background-color:#efefef;"| [[Shakir-Khalil and Al-Rawdan 1995, 1996]] | ! scope="row" style="background-color:#efefef;"| [[Shakir-Khalil and Al-Rawdan 1995, 1996]] | ||
+ | | Monotonic test for full-scale simple interior beam-to-column connections of square CFTs | ||
+ | | 4 CFTs | ||
| | | | ||
+ | *Symm. loading of the beams and axial loading of the column, simult. | ||
+ | *Beam-to-column ratios were 1:3, 1:5 or 1:8 | ||
| | | | ||
+ | *M vs. θ<sub>c</sub> | ||
+ | *K<sub>o</sub>, P<sub>u</sub> | ||
+ | *P vs. in-plane displacement along the column length | ||
| | | | ||
− | + | *Beam load-to-column load ratio | |
− | + | *Eccentricity of beam load | |
| | | | ||
|- | |- | ||
! scope="row" style="background-color:#efefef;"| [[Kawano and Matsui 1997]] | ! scope="row" style="background-color:#efefef;"| [[Kawano and Matsui 1997]] | ||
[[Kawano and Matsui 1997 II]] | [[Kawano and Matsui 1997 II]] | ||
+ | | Simple tension tests on CFT and HT connections and cyclic tests on cruciform frames including both CFTs and HTs | ||
| | | | ||
+ | *6 CFTs, 9 HTs (simple tension) | ||
+ | *9 CFTs, 11 HTs (cruciform frame) | ||
| | | | ||
+ | *Tensile loading until fracture through flanges (smpl. tension test) | ||
+ | *Constant axial load on the columns and cyclic shear force at the girder ends (cruciform frames) | ||
| | | | ||
+ | *P<sub>u</sub>, P<sub>a</sub>, P<sub>u</sub>/P<sub>a</sub> | ||
+ | *V<sub>u</sub>/V<sub>c</sub> | ||
+ | *V vs. R | ||
| | | | ||
− | + | *CFT vs. HT | |
+ | *Connection type | ||
+ | *Size of diaphragm and vertical stiffener | ||
| | | | ||
|- | |- | ||
! scope="row" style="background-color:#efefef;"| [[Schneider and Alostaz 1998]] | ! scope="row" style="background-color:#efefef;"| [[Schneider and Alostaz 1998]] | ||
− | | | + | | Cyclic testing of 2/3 scale beam-to-column connections of circular CFTs |
− | | | + | | 6 CFTs |
− | | | + | | Constant axial load on to the column and cyclic shear load at the girder end |
− | | | + | | M vs. θ, M<sub>c</sub> |
− | | | + | | Connection details |
| | | | ||
|- | |- | ||
! scope="row" style="background-color:#efefef;"| [[France, Davison, and Kirby 1999]] | ! scope="row" style="background-color:#efefef;"| [[France, Davison, and Kirby 1999]] | ||
+ | | Cyclic and monotonic loading of beam-to-column flow-drill connections of square CFTs and HTs | ||
| | | | ||
+ | *20 HTs | ||
+ | *6 CFTs | ||
+ | | Monotonic or cyclic shear force applied at the girder tips with either constant or no axial load acting on the columns | ||
+ | | M vs. θ, M<sub>u</sub>, θ<sub>u</sub> | ||
| | | | ||
− | + | *CFT vs. HT | |
− | + | *Connection type (simple or fully restrained) | |
− | + | *Beam size | |
+ | *t | ||
+ | *P | ||
+ | *Bolt spacing | ||
+ | *Endplate type | ||
+ | *f<sub>y</sub> | ||
| | | | ||
− | | | + | |- |
! scope="row" style="background-color:#efefef;"| [[Cheng, Hwang, and Chung 2000]] | ! scope="row" style="background-color:#efefef;"| [[Cheng, Hwang, and Chung 2000]] | ||
+ | | Cyclic loading of beam-to-column connections of circular CFTs | ||
| | | | ||
+ | *3 CFTs | ||
+ | *3 HTs | ||
+ | | Constant axial load on the columns and cyclic shear load at the girder ends | ||
| | | | ||
+ | *V vs. girder-end deflection | ||
+ | *Contribution of girder, column, and panel zone to the total deformation | ||
| | | | ||
− | + | *CFT vs. HT | |
− | + | *D/t | |
+ | *Connection type | ||
| | | | ||
|} | |} | ||
Line 104: | Line 176: | ||
{| style="color:black; background-color:white;" width="100%" cellpadding=1 cellspacing="0" border="1" style="font-size: 90%;" | {| style="color:black; background-color:white;" width="100%" cellpadding=1 cellspacing="0" border="1" style="font-size: 90%;" | ||
|- | |- | ||
+ | ! scope="col" style="width: 10%;background-color:#efefef;" | Reference | ||
! scope="col" style="width: 10%;background-color:#efefef;" | Beam Information | ! scope="col" style="width: 10%;background-color:#efefef;" | Beam Information | ||
! scope="col" style="width: 15%;background-color:#efefef;" | Connection Information | ! scope="col" style="width: 15%;background-color:#efefef;" | Connection Information | ||
Line 158: | Line 231: | ||
| | | | ||
| | | | ||
− | | | + | |- |
! scope="row" style="background-color:#efefef;"| [[Cheng, Hwang, and Chung 2000]] | ! scope="row" style="background-color:#efefef;"| [[Cheng, Hwang, and Chung 2000]] | ||
| | | | ||
Line 234: | Line 307: | ||
| | | | ||
| | | | ||
− | | | + | |- |
! scope="row" style="background-color:#efefef;"| [[Cheng, Hwang, and Chung 2000]] | ! scope="row" style="background-color:#efefef;"| [[Cheng, Hwang, and Chung 2000]] | ||
| | | |
Revision as of 02:08, 6 March 2012
General Information
Reference | Experiment Synopsis | Number of Tests | Loading Method | Results Reported | Main Parameters | Comments |
---|---|---|---|---|---|---|
Dunberry, LeBlanc, and Redwood 1987 | Axial loading of square stub columns through shear connections | 18 CFTs | Axial load applied at the top and at the connection simultaneously |
|
|
|
Kamba, Kanatani, and Tabuchi 1991 | Shear tests of through diaphragm connections to square CFT and HT columns |
|
Shear couples acting on the diaphragm plates |
|
|
|
Prion and McLellan 1992 | Through-bolt connections between steel wide-flange girders and CFTs | 8 CFTs | Tension pull-out and compression pull-in tests |
|
Post-tensioning of the bolts in the connection | |
Azizinamini and Prakash 1992 | Pass-through girder with internal stiffeners | 1 CFT | Shear forces were applied to the girder ends in opposite directions | N.A. | N.A. | |
Shakir-Khalil and Al-Rawdan 1995, 1996 | Full-scale simple interior beam-to-column connections of circular and square CFTs | 28 CFTs |
|
|
|
|
Shakir-Khalil and Al-Rawdan 1995, 1996 | Monotonic tests for full-scale simple exterior beam-to-column connections of square CFTs | 4 CFTs |
|
|
|
|
Shakir-Khalil and Al-Rawdan 1995, 1996 | Monotonic test for full-scale simple interior beam-to-column connections of square CFTs | 4 CFTs |
|
|
|
|
Kawano and Matsui 1997 | Simple tension tests on CFT and HT connections and cyclic tests on cruciform frames including both CFTs and HTs |
|
|
|
|
|
Schneider and Alostaz 1998 | Cyclic testing of 2/3 scale beam-to-column connections of circular CFTs | 6 CFTs | Constant axial load on to the column and cyclic shear load at the girder end | M vs. θ, Mc | Connection details | |
France, Davison, and Kirby 1999 | Cyclic and monotonic loading of beam-to-column flow-drill connections of square CFTs and HTs |
|
Monotonic or cyclic shear force applied at the girder tips with either constant or no axial load acting on the columns | M vs. θ, Mu, θu |
|
|
Cheng, Hwang, and Chung 2000 | Cyclic loading of beam-to-column connections of circular CFTs |
|
Constant axial load on the columns and cyclic shear load at the girder ends |
|
|
Specimen Information
Cross Section Information
◌: diam. (D) □: depth (D) x width: 5.88 x 5.88 Wall Thickness (t) (in): 0.166-0.170 Diameter/thickness (D/t): 35
- Grade 4.6 Black bolts