Difference between revisions of "Table of Experimental Studies on Beam, Beam Column, and Shear Tests"
From Composite Systems
(→Cross Section Information) |
(→Cross Section Information) |
||
(16 intermediate revisions by 2 users not shown) | |||
Line 574: | Line 574: | ||
*f′<sub>c</sub> | *f′<sub>c</sub> | ||
*Orientation | *Orientation | ||
+ | | | ||
+ | |- | ||
+ | ! scope="row" style="background-color:#efefef;"| [[Inai, Mukai, Kai, Tokinya, Fukumoto and Mori 2004]] | ||
+ | | Circular and square CFT beam columns with varying dimensions were tested under constant axial load and varying lateral load to determine the effects on the ductility of CFT beam columns. | ||
+ | | | ||
+ | 34 (bmcol) | ||
+ | | | ||
+ | *Constant axial load | ||
+ | *Cyclically varying lateral load | ||
+ | | | ||
+ | *Moment-curvature | ||
+ | *Axial strain-curvature | ||
+ | | | ||
+ | *f<sub>y</sub> | ||
+ | *f'c | ||
+ | *D/t | ||
| | | | ||
|- | |- | ||
Line 637: | Line 653: | ||
*Variable amplitude loading | *Variable amplitude loading | ||
*Constant amplitude loading histories | *Constant amplitude loading histories | ||
+ | | | ||
+ | |- | ||
+ | ! scope="row" style="background-color:#efefef;"| [[Perea et al. 2013]] | ||
+ | | Full Scale Slender CFT Beam-Columns | ||
+ | | 18 CFT (10 circular and 8 rectangular) | ||
+ | | | ||
+ | *Concentric axial compression | ||
+ | *Axial compression plus uniaxial cyclic bending | ||
+ | *Axial compression plus biaxial cyclic bending | ||
+ | | | ||
+ | *Load | ||
+ | *Displacement | ||
+ | *Curvatures | ||
+ | | | ||
+ | *Section shape and size | ||
+ | *Concrete strength | ||
+ | *Slenderness | ||
+ | *Axial load | ||
+ | | | ||
+ | |- | ||
+ | ! scope="row" style="background-color:#efefef;"| [[Du, Chen, Liew and Xiong 2017]] | ||
+ | | Rectangular CFT beam columns with high-strength steel | ||
+ | | 23 (bmcol) | ||
+ | | | ||
+ | *Axial Load and bending moment | ||
+ | | | ||
+ | *P vs. Δ | ||
+ | *P vs. ε | ||
+ | | | ||
+ | *In-fill concrete | ||
+ | *eccentricity | ||
+ | *D/t | ||
+ | *Slenderness | ||
| | | | ||
|- | |- | ||
Line 916: | Line 965: | ||
| N.A. | | N.A. | ||
| Fixed-free | | Fixed-free | ||
+ | |- | ||
+ | ! scope="row" style="background-color:#efefef;"| [[Inai, Mukai, Kai, Tokinya, Fukumoto and Mori 2004]] | ||
+ | | 37.56-56.93 | ||
+ | | 6 | ||
+ | | N.A. | ||
+ | | N.A. | ||
+ | | Pinned-pinned | ||
|- | |- | ||
! scope="row" style="background-color:#efefef;"| [[Wheeler and Bridge 2004]] | ! scope="row" style="background-color:#efefef;"| [[Wheeler and Bridge 2004]] | ||
Line 946: | Line 1,002: | ||
| N.A. | | N.A. | ||
| Column fixed at base | | Column fixed at base | ||
+ | |- | ||
+ | ! scope="row" style="background-color:#efefef;"| [[Perea et al. 2013]] | ||
+ | | 216-312 | ||
+ | | 10.8-56.1 | ||
+ | | N.A. | ||
+ | | Not Measured | ||
+ | | Column fixed at base | ||
+ | |- | ||
+ | ! scope="row" style="background-color:#efefef;"| [[Du, Chen, Liew and Xiong 2017]] | ||
+ | | N.A. | ||
+ | | N.A. | ||
+ | | .41-2.96 | ||
+ | | N.A. | ||
+ | | Pinned-pinned | ||
|- | |- | ||
|} | |} | ||
Line 1,224: | Line 1,294: | ||
F<sub>y</sub>= 56-59 ksi | F<sub>y</sub>= 56-59 ksi | ||
| f'<sub>c</sub>= 5.8-14.9 ksi | | f'<sub>c</sub>= 5.8-14.9 ksi | ||
+ | |- | ||
+ | ! scope="row" style="background-color:#efefef;"| [[Inai, Mukai, Kai, Tokinya, Fukumoto and Mori 2004]] | ||
+ | | | ||
+ | *'''◌: diam. (D) □: depth (D) x width:''' 6.30, 9.45 (Circle), 7.09x7.09, 8.27x8.27 (square) | ||
+ | *'''Wall Thickness (t) (in):''' 0.178-.354 | ||
+ | *'''Diameter/thickness (D/t):''' 17.80-53.09 | ||
+ | | F<sub>y</sub>= 58.02-113.13 ksi | ||
+ | | f'<sub>c</sub>= 5.08, 13.05 ksi | ||
|- | |- | ||
! scope="row" style="background-color:#efefef;"| [[Wheeler and Bridge 2004]] | ! scope="row" style="background-color:#efefef;"| [[Wheeler and Bridge 2004]] | ||
Line 1,259: | Line 1,337: | ||
F<sub>y</sub>= 42.5 ksi | F<sub>y</sub>= 42.5 ksi | ||
| f'<sub>c</sub>= 4.70 (CFT), 8.38 (SCFT) ksi | | f'<sub>c</sub>= 4.70 (CFT), 8.38 (SCFT) ksi | ||
+ | |- | ||
+ | ! scope="row" style="background-color:#efefef;"| [[Perea et al. 2013]] | ||
+ | | | ||
+ | * HSS5.563X0.134 | ||
+ | * HSS12.750X0.250 | ||
+ | * HSS20.000X0.250 | ||
+ | * HSS20X12X5/16 | ||
+ | | F<sub>y</sub> = 42 ksi-55 ksi | ||
+ | | f'<sub>c</sub> = 5.5 ksi-13.3 ksi | ||
+ | |- | ||
+ | ! scope="row" style="background-color:#efefef;"| [[Du, Chen, Liew and Xiong 2017]] | ||
+ | | | ||
+ | * *'''◌: diam. (D) □: depth (D) x width:''' 4.72x3.94, 7.09x4.72, 9.57x5.31 | ||
+ | *'''Wall Thickness (t) (in):''' .224 | ||
+ | *'''Diameter/thickness (D/t):''' 21.05, 31.58, 42.63 | ||
+ | | High Strength Steel | ||
+ | F<sub>y</sub> = 74.62 ksi | ||
+ | | C40 and C50 grade | ||
+ | f'<sub>c</sub> = 8.02, 6.27 ksi | ||
|- | |- | ||
|} | |} | ||
+ | |||
+ | [[Category:Tables]] |
Latest revision as of 20:10, 23 March 2020
General Information
Reference | Experiment Synopsis | Number of Tests | Loading Method | Results Reported | Main Parameters | Comments |
---|---|---|---|---|---|---|
Furlong 1967 | Ultimate strength of CFT bm-cols. (experimental vs. theoretical) | 52 CFTs (13 col, 39 bmcol) |
|
|
|
|
Furlong 1968 | Design of CFT bmcols; previous exps. examined | 28 CFTs (col) (tests by others tabulated); also includes 52 CFTs from Furlong, '67 | N.A. |
|
|
Analytical formulas presented and discussed |
Tomii and Sakino 1979 a & b | Examination of M-P-φ relationship for square CFTs |
|
|
|
|
|
Tomii and Sakino 1979 c | Shear behavior of square CFTs | 40 CFTs (bmcol) |
|
|
|
|
Sakino and Tomii 1981 | Hysteretic behavior of beam-columns failing in flexure | 15 CFTs (bmcol) |
|
|
|
|
Sakino and Ishibashi 1985 | Monotonic and hysteretic behavior of beam-columns failing in shear | 21 CFTs (bmcol) (12 monotonic, 9 cyclic) |
|
|
|
|
Matsui and Tsuda 1987 | Axial load & bending (cyclic & monotonic) |
|
|
|
|
Excellent load-defl. curves |
Cai 1988 | 7 test phases:
|
|
|
|
|
|
Prion and Boehme 1989 |
|
|
|
|
|
|
Konno, Kai, and Nagashima 1990 | Cyclic loading of square CFT bmcols | 19 CFTs (bmcol) |
|
|
|
Compared w/ proposed design equations. |
Huang, Huang, and Zhong 1991 | Cyclic, lateral loading of CFTs | 46 CFTs (bmcol) | Lateral load applied via a frame fixed to top of beam |
|
|
Monotonic and cyclic loading |
Ichinohe et al. 1991 | Monotonic & cyclic loading of CFTs w/ high-strength steel & concrete |
|
|
|
|
|
Sato, Saito, and Suzuki 1991 | Reversed cyclic shear loading of circular CFTs | 3 CFTs |
|
|
|
|
Sugano, Nagashima, and Kei 1992 | Cyclic loading of square and circular beam-columns |
|
|
|
|
|
Kawaguchi et al. 1993 | Cyclic loading of cantilever CFT beam-columns |
|
N.A. |
|
|
|
Lu and Kennedy 1994 | Monotonic uniaxial loading (pure bending, simple supports) of rectangular CFTs |
|
|
|
|
|
Sakino 1995 | Monotonic loading of circular CFT beam-columns | 28 CFTs (bmcol) |
|
|
P/Po for given cyclic loading | |
Fujimoto et al. 1996 & Inai et al. 2004 | Cyclic load-deformation and ultimate strength of CFT beam-columns with variable axial load |
|
|
|
|
|
Tsuda, Matsui, and Mino 1996 | Series II - Slender Cantilever CFT’s subjected to cyclic horizontal load while under constant axial load |
|
|
|
|
|
El-Remaily et al. 1997 | Cyclic loading of circular CFTs w/ high strength concrete | 4 CFTs (cyclic) |
|
|
|
|
Zhang and Shahrooz 1997 | Monotonic loading of square CFT beam-columns at a horizontal position | 2 CFTs (bmcol) | Constant axial load, monotically increasing point loads applied at two points along the specimen length |
|
Axial load ratio P/Po | |
Nakahara and Sakino 1998 | Monotonic loading of square hollow tubes and square CFTs w/ high strength concrete and steel |
|
|
|
|
|
Nakahara and Sakino 2000a | Monotonic and cyclic loading of square CFT bmcols |
|
|
|
|
|
Varma et al. 2000, 2001, 2002, 2004 | Monotonic and cyclic loading of square CFTs w/ high-strength steel & concrete |
|
|
|
|
|
Elchalakani, Zhao, and Grzebieta 2001 | Uniaxial flexural loading (pure bending) of circular CFT beams | 12 CFTs |
|
|
|
|
Elremaily and Azizinamini 2002 | Non-proportional cyclic loading of circular CFT beam-columns | 6 |
|
|
|
|
Hsu and Yu 2003 | Non-proportional cyclic loading of square CFT beam-columns with tie-rods | 18 |
|
|
|
|
Elchalakani, Zhao, and Grzebieta 2004 | Constant amplitude cyclic flexural loading (pure bending) of circular CFT beams | 23 |
|
|
|
|
Fujimoto et al. 2004 | Monotonic loading of short circular and square CFT beam columns | 65 | Three types:
|
|
|
|
Hardika and Gardner 2004 | Non-proportional cyclic loading of square CFT beam-columns | 24 |
|
|
|
|
Inai, Mukai, Kai, Tokinya, Fukumoto and Mori 2004 | Circular and square CFT beam columns with varying dimensions were tested under constant axial load and varying lateral load to determine the effects on the ductility of CFT beam columns. |
34 (bmcol) |
|
|
|
|
Wheeler and Bridge 2004 | Monotonic four point bending of circular CFT beams |
|
|
|
D/t f′c |
|
Han and Yang 2005 | Non-proportional cyclic loading of circular CFT beam columns |
|
|
H vs. Δ |
|
|
Elchalakani and Zhao 2008 | Variable amplitude cyclic flexural loading (pure bending) of circular CFT beams | 10 CFTs |
|
|
|
|
Gajalakshmi and Helena 2012 |
|
|
|
|
||
Perea et al. 2013 | Full Scale Slender CFT Beam-Columns | 18 CFT (10 circular and 8 rectangular) |
|
|
|
|
Du, Chen, Liew and Xiong 2017 | Rectangular CFT beam columns with high-strength steel | 23 (bmcol) |
|
|
|
Specimen Information
Reference | Length (L)(in) | L/D | Eccentricity(in) | Residual Stresses(ksi) | End Conditions |
---|---|---|---|---|---|
Furlong 1967 | Approx. 36.0 | 5.5-12.0 | Constant for all tests | N.A. |
|
Furlong 1968 | 33.9-102 | 8.7-40.0 | N.A. | Extensive stresses noted in plain tube tests | N.A. |
Tomii and Sakino 1979 a & b | 11.8 | 3.0 | N.A. | Tubes annealed |
|
Tomii and Sakino 1979 c | 6.5-23.6 | 1.66-6.0 (a/D = 0.83-3.0) | N.A. | Tubes annealed |
|
Sakino and Tomii 1981 | 15.7-23.6 | 4.0-6.0 (a/D = 2.0-3.0) | N.A. | Tubes annealed |
|
Sakino and Ishibashi 1985 | 7.9-11.8 | 2.0-3.0 (a/D = 1.0-1.5) | N.A. | Tubes annealed |
|
Matsui and Tsuda 1987 | 29.5 | 5.0 | N.A. | N.A. | Vertical cantilever:
fixed base, free end |
Cai 1988 | see L/D |
1) <= 4.0 2) 3-50 3) ? 4) 4-22 5) 5-13 6) 9-19 7) 4-8 |
e / (concrete radius) = 0-1.28 | N.A. |
|
Prion and Boehme 1989 |
|
|
3 bmcol tests:
0.43-0.59 |
N.A. |
|
Konno, Kai, and Nagashima 1990 | 66.9 | 6.8 | N.A. | N.A. | Pinned-pinned |
Huang, Huang, and Zhong 1991 | 35.4-65.4 | 5.45-17.5 (λ = 22-75) | N.A. | N.A. |
|
Ichinohe et al. 1991 | 35.4, 90.6 |
|
N.A. | Annealed specimens noted | Both pinned-pinned |
Sato, Saito, and Suzuki 1991 | 43.3 | 7.33 | N.A. | Annealed |
|
Sugano, Nagashima, and Kei 1992 |
|
|
N.A. | N.A. | Pinned transverse supports |
Kawaguchi et al. 1993 | 39.3 (1 m) | 10 | N.A. | N.A. | Fixed base, pinned top (roller) |
Lu and Kennedy 1994 | 77.75-167.72 | 8.78-20 | Pure bending | N.A. | Simply supported beam with load applied symmetrically at two points. Stiffeners under loads |
Sakino 1995 | 12.75-53.15 | 3 | N.A. | N.A. | Two loading plates welded to the ends |
Fujimoto et al. 1996 & Inai et al. 2004 | 37.8-56.7 | 6 | N.A. | N.A. | Fixed CFT columns attached to CFT stubs at ends to guarantee sufficient stiffness |
Tsuda, Matsui, and Mino 1996 | All noted are kL;
|
|
N.A. | N.A. | Col: Fixed base, unspecified connection at top (poss. free or pin) |
El-Remaily et al. 1997 | 110.83 | 7.16 | N.A. | N.A. | Pinned ends, rigid stub at the midheight |
Zhang and Shahrooz 1997 | 143.98 | 14.4 | N.A. | N.A. | Pinned ends through cylindrical bearings |
Nakahara and Sakino 1998 | 23.62 | 3 | N.A. | N.A. |
|
Nakahara and Sakino 2000a | 23.62 | 3 | N.A. | Annealed | Two loading plates welded to the ends |
Varma et al. 2000, 2001, 2002, 2004 | 48.03, 58.50, 60.00 | 4.00, 5.00, 4.87 | N.A. | N.A. |
|
Elchalakani, Zhao, and Grzebieta 2001 | 23.62, 31.49 | 5.41-23.68 | N.A. | N.A. | Attached to rotational fixtures at each end |
Elremaily and Azizinamini 2002 | 86 | 6.7 | N.A. | N.A. |
|
Hsu and Yu 2003 | 118 (72.4 effective length) | 10.7 | N.A. | N.A. |
|
Elchalakani, Zhao, and Grzebieta 2004 | 31.5 (length of pure bending) | 7.3-13.1 | Pure bending | N.A. | Attached to rotational fixtures at each end |
Fujimoto et al. 2004 | 12.75-53.1 | 3.0 |
|
N.A. | Either pinned-pinned or fixed-free |
Hardika and Gardner 2004 | 75 | 9.4 | 0.5 in between horizontal load and section centroid | N.A. | Fixed-free |
Inai, Mukai, Kai, Tokinya, Fukumoto and Mori 2004 | 37.56-56.93 | 6 | N.A. | N.A. | Pinned-pinned |
Wheeler and Bridge 2004 | 149.6 | 9.4, 8.3 | N.A. | N.A. | Pinned-pinned |
Han and Yang 2005 | 59 |
|
N.A. | N.A. | Pinned-pinned, cylindrical bearings |
Elchalakani and Zhao 2008 | 31.5 | 7.3-13.1 | Pure bending | N.A. | Attached to rotational fixtures at each end |
Gajalakshmi and Helena 2012 | 39.37 | 8.77 | N.A. | N.A. | Column fixed at base |
Perea et al. 2013 | 216-312 | 10.8-56.1 | N.A. | Not Measured | Column fixed at base |
Du, Chen, Liew and Xiong 2017 | N.A. | N.A. | .41-2.96 | N.A. | Pinned-pinned |
Cross Section Information
Reference | Tube Dimensions | Steel Properties | Concrete Properties |
---|---|---|---|
Furlong 1967 |
|
Seam-weld cold-rolled
Fy= 42.0-60.0 ksi (circular) 48.0-70.3 ksi (rect.) |
f'c= 3.05-5.10 ksi (circular) 3.40-6.50 ksi (rect.) |
Furlong 1968 |
|
Seam-welded cold-rolled
Fy= 39.6-76.0 ksi |
f'c= 2-5 ksi |
Tomii and Sakino 1979 a & b |
|
Mild cold-worked, welded, annealed
Fy= 28.7-50.2 ksi |
f'c= 2.7-5.5 ksi |
Tomii and Sakino 1979 c |
|
Mild, cold-worked, welded, annealed
Fy= 28.2-44.9 ksi |
f'c= 3.3-6.6 ksi |
Sakino and Tomii 1981 |
|
Mild, cold-worked, welded, annealed
Fy= 42.1-44.9 ksi |
f'c= 2.9-3.7 ksi |
Sakino and Ishibashi 1985 |
|
Mild, cold-worked, welded, annealed
Fy= 41.8-45.8 ksi |
f'c= 2.4-3.7 ksi |
Matsui and Tsuda 1987 |
|
Mild-steel plates
Fy= 51.4-71.5 ksi |
f'c= 4.6-6.0 ksi |
Cai 1988 |
|
N.A. | N.A. |
Prion and Boehme 1989 |
|
Electrically welded long. seam
Fy= 36-48 ksi |
f'c= 10.6-13.3 ksi |
Konno, Kai, and Nagashima 1990 |
|
Fy= 45.9-69.3 | f'c= 4.38- 12.31 ksi |
Huang, Huang, and Zhong 1991 |
|
Fy= 34.2-44.1 ksi | f'c= 3.96-5.32 ksi |
Ichinohe et al. 1991 |
|
Some specimens annealed
Fy= 50.8-85.3 ksi |
f'c= 9.0-9.6 ksi |
Sato, Saito, and Suzuki 1991 |
|
Annealed
Fy= 55.8 ksi |
f'c= 5.15 ksi |
Sugano, Nagashima, and Kei 1992 |
|
Fy= 47.9-72.1 ksi | f'c= 4.5-12.8 ksi |
Kawaguchi et al. 1993 |
|
Cold-formed
Fy= 49.2 ksi |
f'c= 3.1-3.6 ksi |
Lu and Kennedy 1994 |
|
Cold-formed
Fy= 50 ksi |
f'c= 5.87-6.83 ksi |
Sakino 1995 |
|
Fy= 59.2, 93.7, 127.5 ksi | f'c= |
Fujimoto et al. 1996 & Inai et al. 2004 |
|
Cold-formed
Fy= 58.0, 85.6, 113.1 ksi |
f'c= 5.80, 13.05 ksi |
Tsuda, Matsui, and Mino 1996 |
|
Mild steel;
Fy= STK 400: 51.5 ksi, STKR 400: 57.5 ksi |
f'c= 5.04 ksi |
El-Remaily et al. 1997 |
|
Fy= 54 | f'c= 10, 15 ksi |
Zhang and Shahrooz 1997 |
|
Cold- formed
Fy= 53.7 ksi |
f'c= 6.05 ksi |
Nakahara and Sakino 1998 |
|
Cold-formed channel sections
Fy= 45.0, 113.3 ksi |
f'c= 17.26 ksi |
Nakahara and Sakino 2000a |
|
Fy= 30.6, 36.7, 46.4 ksi | f'c= 6.90 ksi |
Varma et al. 2000, 2001, 2002, 2004 |
|
A500
A500 Fy= Grade B: 37.6, 68.3 ksi, Grade 80: 81.2, 95.7 ksi |
f'c= 4.33 ksi |
Elchalakani, Zhao, and Grzebieta 2001 |
|
Cold-formed
Fy= 52.9-66.7 ksi |
f'c= 3.39 ksi |
Elremaily and Azizinamini 2002 |
|
Fy= 54 ksi |
f'c= 5.8-15.1 ksi |
Hsu and Yu 2003 |
|
Cold bent JIS SS-400 plates
Fy= 46.5 ksi |
f'c= 4.93 ksi |
Elchalakani, Zhao, and Grzebieta 2004 |
|
Cold formed, electric resistance welded
Fy= 60.6 ksi |
f'c= 3.35 ksi |
Fujimoto et al. 2004 |
|
Cold formed plate
Circular: cold form and seam weld Square: welding two channels Fy= 38-121 ksi |
f'c= 3.7-12.3 ksi |
Hardika and Gardner 2004 |
|
ASTM A 500 Grade C
Fy= 56-59 ksi |
f'c= 5.8-14.9 ksi |
Inai, Mukai, Kai, Tokinya, Fukumoto and Mori 2004 |
|
Fy= 58.02-113.13 ksi | f'c= 5.08, 13.05 ksi |
Wheeler and Bridge 2004 |
|
Cold rolled with continuous seamless welds
Fy= 50.9 ksi |
f'c= 5.8-8.1 ksi |
Han and Yang 2005 |
|
Fy= 51.6, 44.7 ksi | f'c= 3.2, 5.6 ksi |
Elchalakani and Zhao 2008 |
|
Cold formed (in some cases machined to achieve D/t)
Fy= 61.4 ksi |
f'c= 3.35 ksi |
Gajalakshmi and Helena 2012 |
|
Fy= 42.5 ksi |
f'c= 4.70 (CFT), 8.38 (SCFT) ksi |
Perea et al. 2013 |
|
Fy = 42 ksi-55 ksi | f'c = 5.5 ksi-13.3 ksi |
Du, Chen, Liew and Xiong 2017 |
|
High Strength Steel
Fy = 74.62 ksi |
C40 and C50 grade
f'c = 8.02, 6.27 ksi |